Factory Act 1948, Section 38-1 control measure should be taken to prevent spread the fire inside & outside every factory.
A) Safe equipment for all persons to exit in case of fire.
B) Fire extinguisher, Sprinkler etc safety equipment available in every factory for control the fire.
Fire Extinguisher Types
There are 5 main types
- Water
- Foam
- Dry powder
- Carbon dioxide
- Wet chemical
Fire Extinguisher Parts
- Discharge lever
- Holding / carrying handle
- Seal / safety pin / lock pin
- Pressure gauge
- Discharge Hose
- Discharge Nozzle
- cylinder
Water Fire Extinguisher
Water extinguisher are the most common type of fire extinguisher for CLASS A fire.
Label color : Bright Read
Water extinguisher use for organic material Paper, Wood.
Do not use for fire involving electrical equipment, kitchen fire, flammable fire.
Water Extinguisher working cooling principle.
Water Extinguisher are 3 types
- Soda Acid : Sodium Bi-Carbonate + Sulphuric Acid = Co2 gas which pressurized water
- CO2 Cartridge : Water + Co2 cartridge = Co2 gas which pressurized water
- Stored Pressure : Water + N2 = Pressurized water
Water Type Fire Extinguisher Capacity : 6 ltr & 9 ltr
Water Fire Extinguisher Specification
9 Liter stored pressure water type fire extinguisher as per indan Standard 15683 with rating Of 3A.
Extinguisher media : Water (80%) + N2 (20%) ( N2 Gas is Unreactive, Un flammable )
Operating pressure : Nitrogen pressure with 10 to 15 Bar
Hydro test : 35 Bar with in 2.5 minutes
Brust pressure : 55 Bar
Fire fighting range : 2 meter minimum effective range
This extinguisher working in -5 to 60 degree Celsius.
Minimum test to be preformed : Hydro test , fire rating, resistance to temperature, internal and external corrosion test, crushing test, vibration test and air aging plastics test.
Discharge percentage : Not less than 90%
Foam Type Fire Extinguisher
Foam type extinguisher are most common type of fire extinguisher for CLASS B fires but also work on class A Fire they are water based.
Label color :Green
Foam extinguisher are use for organic material Ex. Paper, wood, flammable liquid.
Don’t use for kitchen fire, fire involving electric equipment, flammable material, flammable metal.
Foam Extinguisher working colling and smothering method.
It is available in 9 Ltr cylinder and used in 4 to 6 mt range.
It is available in wheel mounted trolley of 18 Ltr and 150 Ltr capacity for longer use
Foam Fire Extinguisher Use : Class A & B fire
Foam Type Fire Extinguisher
There are three type of foam compound :
- Mechanical Foam
- Chemical Foam
- Synthetic Foam
Foam Concentration Types
Type 1:-99% water 1% concentrate
Type 3:-97% water 3% concentrate
Type 6:- 94% water 6% concentrate
Mechanical Foam are three types
AFFF (Aqueous film forming foam) : A foam concentrate that has a fluorinated surfactant with stabilizing additive and synthetic surfactants foaming agents for Class A and B fires
FFFP (film forming Fluro protein) : A foam concentrate that is protein base with one or more fluorinated surfactant additives for Class A and B fires.
AR-FFF (Alcohol resistance aqueous film forming foam) : A foam concentrate that has a fluorinated surfactant with stabilizing additive of Polysaccharide and synthetic surfactants foaming agents for Class A and B fires.
Chemical Foam
Protein : A foam concentrate that has a hydrolyzed protein base with stabilizing additives suitable for Class A and B fires.
Fluro Proteins : A foam concentrate that is protein base with one or more fluorinated surfactant additives for Class A and B fires.
Foam Fire Extinguisher Specification
Extinguisher media : Water 94% and 6% Foam
Operating pressure : Nitrogen pressure with 12 Bar
Hydro test : 35 Bar with in 30 second
Fire fighting range : 2 meter minimum effective range
This extinguisher working in -5 to 60 degree Celsius.
Minimum Discharge time : 15 second
Dry Powder Fire Extinguisher
This can be used on any class of fire. Therefore it is known as ‘universal type extinguisher’. It is generally used on fire of flammable liquid.
Standard dry powder extinguisher are also called “ A B C “ extinguisher because they tackle class A, B and C fires.
Label Color : Blue
Use for Organic material, Ex. Paper, cardboard wood
Flammable liquid Ex. Paint, petrol, solvent
Flammable gases Ex. Liquid petroleum gas (LPG) and acetylene.
Dry Powder Fire Extinguisher Contain are Mono Ammonium Phosphate, Sodium Bi-Carbonate and Ternary Eutectic Chloride.
Dry Powder Fire Extinguisher Use For CLASS (A B C) Fire.
Dry Powder Fire Extinguisher Specification
Operating pressure : Nitrogen pressure with 10 to 15 Bar
Extinguisher capacity : 1 kg, 2 kg, 4 kg, 6 kg, 9 kg
Hydro test : 35 Bar with in 30 Second
Brust pressure : 55 Bar in 1 minutes
Fire fighting range : 2 meter minimum effective range
This extinguisher working in -30 to 60 degree Celsius.
Co2 Fire Extinguisher
It is useful on class E i.e. electrical fire because CO2 is nonconductive gas.
CO2 extinguisher are predominantly used for risk and are usually the main fire extinguisher type provided in computer server room and electrical panel room.
Carbon dioxide extinguisher work by displaced oxygen or taking away from the oxygen element of fire tringle.
Carbon dioxide is also very cold as it come out of thew extinguisher so cool the fuel.
Co2 are designed for CLASS B fire or electrical fire or flammable liquid.
Label color : Black
Use for flammable liquid Ex. Paint, solvent and petrol, electrical fires
Do not use for : Kitchen fires Combustible materials Ex. Paper wood or textiles Flammable metals
NOTE : It should not be used on fires of metal, sodium, potassium and metal hydrides.
Co2 Fire Extinguisher Specification
Co2 Extinguisher Pressure : 50 Bar
Extinguisher capacity : 2kgs, 3kgs, 4.5kgs, 6.5kgs, 9kgs, 22.5kgs
Hydro test : 250 Bar with in 30 Second
Brust pressure : 350 Bar
Cylinder MOC : Aluminum Grade 6061
Fire fighting range : 3-5 feet minimum effective range
This extinguisher working in -30 to 60 degree Celsius.
All Co2 extinguisher undergo hydrostatic testing and recharge in every 5 year.
Wet Chemical Fire Extinguisher
It is not effective on fire of benzene, ether, EO and CS2 For metal fire, special powder extinguishers are available
Wet chemical extinguisher are designed for use on CLASS K fires. Involving cooking oil and fats.
Wet chemical is extinguishes the fire by removing the heat of fire tringle and prevent reignition by creating a barrier between oxygen and fuel element.
Label Color : Yellow
Wet Chemical Fire Extinguisher Use for cooking oil and fats fire.
Do not use for flammable liquid or gas fires, electrical fire and flammable material.
Halon Fire Extinguisher
Halon 1011, 1211 or 1301 a liquid gas is filled in extinguishers. It is used in place of CO extinguishers but is lighter in comparison.
Halon Fire Extinguisher Use For class B and C fires.
Halon is a fast extinguishing agent. It is ideal for intense and rapid fires. It is non-conductive and leaves no traces when applied. Therefore it is also suitable for electrical fires, computer rooms etc.
Halon is stored under pressure in a cylinder.
A squeeze grip type nozzle is provided on top of the cylinder valve depending upon capacity.
It is available in 2, 4, 5, 25 and 50 kg capacities.
Mostly two types of Halons (halogenated agents) Fire Extinguisher are used :
(1) Halon 1211-Bromochloro difluro methane i.e. CF2BrCI
(2) Halon 1301 – Bromo trifluro methane CF2Br.
Fire Extinguisher PASS Method
Pull the pin : This will allow to discharge the extinguisher.
Aim the base of the fire : Hit the fuel base on fire.
Squeeze the handle : press the button that releases the pressurized extinguisher agent.
Sweep from side to side : until the fire is completely extinguish.
(Note : Extinguisher use from safe distance away 2 meter )
Fire Extinguisher Precautions
- Never use water to extinguish an electrical fire.
- Never place anything in front of fire extinguisher.
- Fire extinguisher must be inspected regularly at least once month.
Advantage
It is used to extinguish fire and protect our houses, industries and offices.
It is occupy very less price.
The device is long lasting. extinguisher life is 12 to 15 year. you can also refill other type.
Disadvantage
An user must have a knowledge of extinguisher it should be used.
Read More : Hazard Type